close

Se connecter

Se connecter avec OpenID

amendment / modification 002

IntégréTéléchargement
RETURN BIDS TO:
RETOURNER LES SOUMISSIONS Á:
Parks Canada Agency
1300 - 635 8 Ave SW
Calgary, AB T2P3M3
Bid Fax: (403) 292-4475
AMENDMENT / MODIFICATION
Title-Sujet
Cameron Falls & Bay Washrooms
Waterton Lakes National Park
Solicitation No. - No. de l’invitation
Date:
5P420-16-5056/A
May 17, 2016
GETS Reference No. – No de reference de
SEAG
Amendment No. - N° de la modif.
PW-16-00731477
Solicitation Closes:
002
at – á
02:00 PM
Tender To: Parks Canada Agency
We hereby offer to sell to Her Majesty the
Queen in right of Canada, in accordance with
the terms and conditions set out herein,
referred to herein or attached hereto, the
goods, services, and construction listed herein
and on any attached sheets at the price(s) set
out therefor.
F.O.B. - F.A.B.
Soumission aux: l’Agence Parcs Canada
Nous offrons par la présente de vendre à Sa
Majesté la Reine du Chef du Canada, aux
conditions énoncées ou incluses par référence
dans la présente at aux annexes ci-jointes, les
biens, services et construction énumérés ici et
sur toute feuille ci-annexée, au(x) prix
indiqué(s).
002
on – le
May 24, 2016
Plant-Usine: 
Time Zone - Fuseau horaire
MDT - HAR
Destination: 
Other-Autre: 
Address Inquiries to: - Adresser toute demande de renseignements à :
Jen Maheu
Telephone No. - No de téléphone
(403) 292-8502
Fax No. – No de FAX:
(403) 292-4475
Destination of Goods, Services, and Construction:
Destinations des biens, services et construction:
See Herein – Voir ici
TO BE COMPLETED BY THE BIDDER (type or print)
Comments - Commentaries
Vendor/Firm Name
Vendor/Firm Name and Address
Raison sociale et adresse du
fournisseur/de l’entrepreneur
Address - Adresse
Name of person authorized to sign on behalf of the Vendor/Firm
Nom de la personne autorisée a signer au nom du fournisseur/ de l’entrepreneur
Issuing Office - Bureau de distribution
Titale - Titre
Parks Canada Agency
Suite 1300
635 – 8 Ave SW
Calgary, AB T2P3M3
Telephone No. - N° de telephone:
Facsimile No. - N° de télécopieur:
Signature
Date
Solicitation No. - N° de l'invitation
5P420-16-5056/A
Amd. No. - N° de la modif.
002
Buyer - l'acheteur
Jen Maheu
Client Ref. No. - N° de réf. du client
1578/1579
File Name - Nom du dossier
Cameron Falls & Bay Washrooms – Waterton Lakes National Park
Amendment 02
This amendment is being raised to distribute questions and answers from the optional site visit held on
May 12, 2016.
A) Site Visit Attendees
Representative’s Name
Company Name
Nitro Construction
Tony Wolak
Simpson Plumbing
Andrew Koot
Westco Construction
Jean Gagnon
Stranville Projects
Marlin K
D.A. Electric
Marty Jurgens
Link Builders
Ryan Hubley
B) Site Visit Questions and Answers
Q1 What depth are the services?
A1 The sewer and water services at both sites are 1.7M to 1.9M deep and 3M from the buildings.
Q2 Should the Contractor cap off the services at the old washroom?
A2 Yes
Q3 Who does the electrical disconnect of the old washroom?
A3 Parks has retained Fortis to do the disconnect and salvage of the overhead wires and pole for Sept 15
- 2016.
Q4 Who supplies the gas service?
A4 The contractor will coordinate with the local gas company to bring the services to the washrooms. Chief
Mountain Gas Co. will invoice Parks Canada directly for the service installation. The contractor will arrange
to purchase any gas used for construction heating from the gas company.
Q5 Can the Cameron Falls Bridge accommodate heavy equipment?
A5 Yes
Q6 Can the footing depths be 300mm to enable using 1200mm wall forms.
A6 Yes
Q7 Can the Contractor have job trailers, porta pottys, c-cans on the sites?
A7 The Contractor can have job trailers and porta pottys on the sites only.
Q8 Does the Contractor supply washroom signage?
A8 Parks will supply signage for the Contractor to install on entry doors.
Q9 Should equipment be cleaned before coming into the Park?
A9 Refer to Contractor’s Duties in summary of work.
Q10 Is all wiring in conduit?
A10 Yes
Q11 Should the contractor install 50mm styrofoam SM on the top 600mm of the interior concrete walls
below slab?
A11 Yes
Page 2 of 3
Solicitation No. - N° de l'invitation
5P420-16-5056/A
Amd. No. - N° de la modif.
002
Buyer - l'acheteur
Jen Maheu
Client Ref. No. - N° de réf. du client
1578/1579
File Name - Nom du dossier
Cameron Falls & Bay Washrooms – Waterton Lakes National Park
All other terms and conditions remain unchanged.
Page 3 of 3
Auteur
Document
Catégorie
Uncategorized
Affichages
1
Taille du fichier
584 KB
Étiquettes
1/--Pages
signaler